A solution for reusing face masks

Specialists join forces to address shortages of face masks in healthcare
A partnership between Van Straten Medical/GreenCycl and waste recycler Renewi has led to a new process for collecting used face masks from hospitals, sterilising them and returning them for reuse. The partnership helps address the shortage of face masks in medical care. This means used face masks are reused rather than incinerated. Thanks to this partnership, more than 48,000 face masks are given a second life every day.
Van Straten Medical/GreenCycl, TU Delft, Franciscus Gasthuis, including clinical microbiologists Peter de Man and Hans Koeleman, and various other hospitals have developed a method
for sterilising used face masks and testing their permeability. The results show that the filter capacity of the masks tested remains above the 94% threshold. Tests were carried out using steam sterilisation at 121 °C, which did not deform the masks. This sterilisation method has been approved by the RIVM.
The need
Medical staff in hospitals may use a face mask only once, after which it must be discarded in accordance with strict hygiene guidelines. The rise in coronavirus infections and the growing number of patients admitted to hospitals have led to a shortage of face masks.
The process
Renewi supplies hospitals with a plastic lidded drum containing an inner bag in which used face masks are collected. Once both the full bag and the lid have been properly closed, the outside of the drum is disinfected. Renewi collects the full drum and immediately supplies a new one. The full drums are delivered to Van Straten Medical/GreenCycl, where both the face masks and the empty drum are sterilised.
GreenCycl uses steam sterilisation at 121 °C. This inactivates all the micro-organisms associated with coronavirus. The face masks remain usable and are 100% reliable for reuse by medical staff. After sterilisation, the face masks are packed into boxes and delivered back to the hospitals. The collection and return process takes between 24 and 48 hours. A code on the lidded drums and on the face masks before the sterilisation process ensures that healthcare organisations can receive their own masks back.
How to sign up?
Healthcare organisations wishing to reuse used face masks in this way can contact the Renewi Zorgteam on 088-7003114 or at [email protected]
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeCircular business under changing regulations
- SubjectNews